Matrix Single/Double-Sided Lounge Display for Hospital Nursing (Model: NBW-HJ/NBW-HJD)

Functions and Features:
l It is commonly installed above the corridor to make it convenient for nurses to inspect the calling condition.
l Room number, sickbed number and nursing grade will be toggle displayed on the screen when a patient is calling. And each item will blink for ten seconds.
l Room number, sickbed number and nursing grade will be toggle displayed on the screen in turn when more than one patient is calling. And each item will flash for ten seconds. The unit also has memory function.
l Date, month, day, time and ˇ°Keep Silentˇ± or one of other polite expressions will be toggle displayed on the screen.
l The lounge display screen can display three-figure room number and two-figure sickbed number.
l The lounge display can display room number, sickbed number and nursing grade on single side or double sides. And each item will blink for ten seconds.

Installation and Operation
1. Hardwares
1) Installation bracket
2) Connection interface
3) Working voltage: 11-24V
4) Dimension: 1048x140x35mm/ 1048x140x70mm (LxWxH)

           
                      Model: NBW-HJ                                                                       Model: NBW-HJD         

2. Installation and Operation
1) There are two groups of connections of lounge display: One is power cord (+12V, COM); another is data signal cable and power control line (A, B, Ctr).
2) Connect the wires with marks (+12V, COM) on the display to the anode and cathode of the power source (DC12V500mA, included).
3) Connect the three wires with marks (A, B, Ctr, COM) on the display to corresponding binding posts (A, B, Ctr, COM) on the master station.

3. Setup of display screen
1) Setup status: Press the Function key on the master station for about two seconds to enter clock setup menu. Press the Function key again for several times to enter ˇ°Sickroom bed setupˇ± menu, and then press the ˇřor ¨‹ key enter the setup. ˇ°In settingˇ­ˇ± will be displayed on the LCD. You can set corresponding sickroom and sickbed number of each substation at this time.
2) Setup method: No. 1-12 switches on the master station represent ˇ°1ˇ± number key, ˇ°2ˇ± number key, ˇ°3ˇ± number key, ˇ°4ˇ± number key, ˇ°5ˇ± number key, ˇ°6ˇ± number key, ˇ°7ˇ± number key, ˇ°8ˇ± number key, ˇ°9ˇ± number key, ˇ°0ˇ± number key, Cancel key and Confirm key respectively from the top down. Enter the setup menu according to above procedures at first, and then select substation numbers to be set in turn, room numbers and sickbed numbers. For example, if you wan to set No. 13 substation to Room 204 and Sickbed 03, you can press No. 1 and No. 3 switches on the master station (representing No. 13 substation), No. 13 substation will be displayed on the lounge display screen; then press No. 2, No. 10 and No. 4 switches on the master station (representing No. 204 room), No. 204 room will be displayed on the lounge display screen; press No. 10 and No. 3 switches on the master station at last (representing No. 03 bed), No. 03 bed will be displayed on the lounge display screen. Press No. 12 switch (representing Confirm key) to confirm your setting and skip to next substation setup. Press No. 11 switch (representing Cancel key) to modify your setting and cancel the substation in setting. Press the Function key to exit if you have finished all settings.