Download Brochure

ABOUT LONBON

ALL PRODUCTS

NEW PRODUCTS

MSDP PRICES

CONTACT  US

ESPAÑOL

中文

LONBON  INTERCOM
 

Network Intercom System

 

Bank/Window Intercom Kits

 

Bank/Window Intercom Kits w
Customer Scoring

 

Intercoms for  Commercial and
Institutional Applications

 

Elevator exclusive intercom system

Intercoms for Apartments and Schools Intercoms

 

Healthcare and Nurse Calls Applications

 
Hospital ICU visiting system  

Intercoms for Correctional Applications

 

Intercoms for Correctional Visitation Applications

 

Digital and Analog 
Recording Cards

 
Wireless Paging System  
     

LONBON QUEUING

 

Wired Queuing Machine with Touch Screen

 

Wireless Queuing Machine with Touch Screen

 
PC-controlled Queuing System  

Hospital Diagnosis Queuing System

 

Hospital Medicine Taking Ticketer System  
Hospital Auto Registering Machine  
     

LONBON  ALARM

 

Burglary Alarm Set

 

Burglary Alarm

 

Alarm Sensors

 

Magnetic Contacts

 

Alarm Buttons

 

Horns & Sirens

 
Switch & Doorbell  

Accessories

 
   
 
 

       

 

The wiring picture of the elevator intercom system:

The wiring picture of the elevator intercom system
 

 Your Current Page: Home-〉Product Catalog->Lonbon Intercom-> Lonbon elevator intercom system

Product catalog of intercoms system for elevator

       Lonbon Intercoms—Lonbon elevator intercom systemfive-part talkback, the 4-wire system,Elevator exclusive intercom system the DBT series)is specially used for the talkback between the elevator room, the control room of the elevator and the managerial center. It includes the 20-call master station (DBT-20), the 20-call substation (DBT-20G), the 40-call master station (DBT-40), the substation in the elevator room (DBT-A), the metal vandal-proof substation in the elevator room (DBT-AE), the substation in the control room (DBT-B), the relay box (DBT-J), the decode board(Model: DBT-CL) and the monitor statistic software (DBT-W). Our company has the intellectual property right of the evaluation-series products and can carry on research, production and distribution by itself. The following introduced are engineering technical indexes, particular cases and wiring layouts:
The engineering technical indexes of the elevator intercom system(picture).
The particular cases of the elevator intercom system(picture).
The wiring picture of the elevator intercom system (DBT) (picture).
The following id the function introduction of the elevator intercom system:

1、The 20-call master station(model: DBT-20):

Functions:
It can show the alarm from the 20-call substations in

   the elevator room and in the control room and keep

   the alarm in memory.
The effect of the DBT-40 master station can be

   achieved when it is connected with the DBT-20G

   substation.
The master station can detect the substation in the

   elevator room.
The master station and the substation in the elevator

   room can call and talk back mutually.
It can display the alarm from the control room and

    talk back to the substation.
The talkback can be carried on among the substation

    in the elevator room and the substation in the control

    room
The master station has the function to broadcast

    music in the substation in the elevator room.
It can monitor the substation in the elevator room in

   circulation.
 主机与轿厢、机房分机之间每二十路用一条四芯总

    线连接。
●  It is specially used for the talkback among the

    elevator room, the elevator control room and the

    managerial center.
The model of the attached power source: HBT-20-05

   DC18V 2.5A
Size: 220x200x55mm(LxWxH)

浏览说明书

Details about  the 20-call master station

2、The 20-call substation(model: DBT-20G):

Functions:

  The effect of the 40-call master station can be

   achieved when it is connected with the DBT-20

   master station. It has the functions of the master

   station when it is connected with the master station.

The master station can detect the substation in the

   elevator room.
The master station and the substation in the elevator

   room can call and talk back mutually.
It can display the alarm from the control room and

    talk back to the substation.
The talkback can be carried on among the substation

    in the elevator room and the substation in the control

    room
The master station has the function to broadcast

    music in the substation in the elevator room.
It can monitor the substation in the elevator room in

   circulation.

 主机与轿厢、机房分机之间每二十路用一条四芯总

    线连接。
Size: 100x200x55mm(LxWxH)

浏览说明书

Details about The 20-call substation

3、The 40-call master station(model: DBT-40):

Functions:

It can show the alarm from the 40-call substations in

   the elevator room and in the control room and keep

   the alarm in memory.

The master station can detect the substation in the

   elevator room.
The master station and the substation in the elevator

   room can call and talk back mutually.
It can display the alarm from the control room and

    talk back to the substation.
The talkback can be carried on among the substation

    in the elevator room and the substation in the control

    room
The master station has the function to broadcast

    music in the substation in the elevator room.
It can monitor the substation in the elevator room in

   circulation.

 主机与轿厢、机房分机之间每二十路用一条四芯总

    线连接。
●  It is specially used for the talkback among the

    elevator room, the elevator control room and the

    managerial center.
The model of the attached power source: HBT-20-05

    DC18V 2.5A
Size: 320x200x55mm(LxWxH)

浏览说明书

Details about The 40-call master station

4、The substation in the elevator room(model: DBT-A):

Functions:

分机外观镀铬工艺,防电磁干扰。广播级通话音质,

   放音逼真、清晰。
  It can alarm to the master station in the control room

    and can talk back to each other.
  The talkback between the substation and the

    machine room can be carried on.
  The talkback among the substation in the machine

    room and the master station and the substation in

    the elevator room can be carried on.

与主机之间每二十路用一条四芯总线连接。
  Size: 130x110x40mm(LxWxH)

浏览说明书

Details about The substation in the elevator room

5、The Semi-Flush substation in the elevator room(model: DBT-B)

Functions:

超薄分机DBT-B,体积小巧,外形美观。

  It can alarm to the master station in the control room

    and can talk back to each other.
  The talkback between the substation and the

    machine room can be carried on.
  The talkback among the substation in the machine

    room and the master station and the substation in

    the elevator room can be carried on.
与主机之间每二十路用一条四芯总线连接。
  Size: 115x75x18mm(LxWxH)

浏览说明书

Details about The substation in the elevator room

6、The substation in the elevator room(Model: DBT-AE):

Functions:

DBT-AE金属防暴分机是采用镀铬工艺及铝合金面

   板,嵌入式安装(含ABS防火安装底盒、支撑杆及

   内六角固定螺丝),具有电磁干扰、防拆、防人为

   破坏功能。
  It can alarm to the master station in the control room

    and can talk back to each other.
  The talkback between the substation and the

    machine room can be carried on.
  The talkback among the substation in the machine

    room and the master station and the substation in

    the elevator room can be carried on.
与主机之间每二十路用一条四芯总线连接。
Size of metal case::235x170x1mm(LxWxH)
Size of the installation bottom box: 210x150x58mm

   (LxWxH)

浏览说明书

Details about The metal vandal-proof substation

7、The substation in the machine room(model: DBT-D): 

Functions:

It adopts the binary-system coding mode and the sound is lively and clear.
It can alarm to the master station in the control room. The talkback among three parts can go on.
It can choose the substation in the elevator room and talk back to each other.
When it is used with the substation in the elevator room it has the alarm function.
与主机之间每二十路用一条四芯总线连接。
Size: 140x138x55mm(LxWxH)

浏览说明书

Details about The substation in the machine room

8、The relay box(model: DBT-J): Enclosed:Long-distance communication needs the relay box (the conjunction picture)

Functions:
The relay box should be used when the distance

   between the master station and the substation is

   too long or the transmitted signal is too weak or the

   star-like conjunction is adopts.

一进四出接线端,可接四条总线

The attached power supply shall be provided, model:

   HBT-20-05 DC18V 2.5A

与主机、分机间是四芯线连接

Size: 140x156x35mm(LxWxH).

浏览说明书

Details about The relay box

 

9、The decode board(Model: DBT-CL):

功能简介:
若让电梯
、机房对讲和监控、报警联动需用解码板来

   实现。

配合二十路主机……使用,解码板上的DA/B、GND/A

   分别接到主机的第4号、第6号线上(六芯总线)或485

   通讯接口(四芯总线)。

解码板有两种输出方式:a)常闭; b)常开。

每二十路共一块解码板,1-20路之间相互独立。每路

   为一个继电器开关量输出,用来触发联动设备。如摄

   像机、报警主机等。

与主机间是四芯线连接。

Size: 155x153x35mm(LxWxH) 

浏览说明书

Details about The decode board

10、监控统计接线盒(型号:DBT-F1、DBT-F4、DBT-F10、DBT-F16、DBT-F22、DBT-F28、DBT-F32):

功能简介:

选配。须配合监控统计软件(型号:DBT-W)才能

   使用。

与电脑的232串口相连,最多能同时监控统计32台主

  

1路接线盒(型号:DBT-F1)可接1台主机

     4接线盒(型号:DBT-F4)可接4台主机

   10接线盒(型号:DBT-F10)可接10台主机

   16接线盒(型号:DBT-F16)可接16台主机

   22接线盒(型号:DBT-F22)可接22台主机

   28接线盒(型号:DBT-F28)可接28台主机

   32接线盒(型号:DBT-F32)可接32台主机

线盒配送电源,型号:NBW-H-05  12V500mA

尺寸:

   DBT-F1:140x75x35mm(LxWxH);

   DBT-F4:140x75x35mm(LxWxH);

   DBT-F10:280x75x35mm(LxWxH);

   DBT-F16:420x75x35mm(LxWxH);

   DBT-F22:560x75x35mm(LxWxH);

   DBT-F28:700x75x35mm(LxWxH);

   DBT-F32:840x75x35mm(LxWxH)。


 

 
11、The monitor statistic software(model: DBT-W):

Functions:
免费软件。须配合监控统计接线盒(型号:DBT-F1、

   DBT-F4、DBT-F10、DBT-F16、DBT-F22、DBT-F28、

   DBT-F32)方能使用。安装在电脑上,可统计、分析、

   打印报表。

界面直观、数据记录清楚。有利于服务的管理和监

   督。

信息数据同步可实时同步显示每个分机的信息状态

   (即待机、报警、通话三种状态)。

统计信息全面,按Access格式生成报表。可显示分

   机的报警起始时间报警持续时间、通话起始时间、

   通话持续时间;可统计最近的报警通话记录;也可

   对某个分机的所有报警通话记录进行查询;也可按

   每天或每月的所有分机报警通话记录进行查询。

 

HOME   |    FEEDBACK  |   HOW TO ORDER   |   ABOUT LONBON   |    PRODUCT SERIES   |    DISTRIBUTION    |    中文   

LonBon Electronics Inc.     Copyright 1995-2009

Tel:+ 001 (248) 686-2648   Fax:+ 001 (313) 286-8907
 200 S. Wing Street, PO Box 5226, Northville, Michigan 48167-5226 U.S.A.